ADEMCO Security System VISTA-15CN Guide d'installation Page 31

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 132
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 30
6–1
SECTION 6
Wireless Expansion
(5800 System)
••••••••••••••••••••••••••••••••••••••••••••••••••
In This Section
About Wireless Expansion
Installing the 5881/5882 Receiver
Installing the 5800TM Module
About Jam Detection and Reporting
5800 Series Transmitters
Installing 5800 Series Transmitters
••••••••••••••••••••••••••••••••••••••••••••••••••
About Wireless Expansion
In
addition
to its basic wired zones, the VISTA-15/VISTA-15CN control supports up to 26
wireless zones
using an appropriate 5881 (5882 in Canada) type RF receiver. The actual
number of zones supported depends on whether you are using a wired zone expander module.
For example
: If
you are using only four of the wired expansion loops, a
5881H (5882H in
Canada)
RF receiver could add 22 RF zones to the system, using any unused zone numbers
10-35, for a combined total of 26 wired and wireless expansion zones.
The receiver can detect signals from
wireless transmitters
within a nominal range of 200
feet.
RF Receiver No. of Zones
5881L/5882L up to 8
5881M/5882M up to 16
5881H/5882H up to 26
Receiver Supervision
The receiver is supervised. The following conditions causes a Trouble report to be generated
and
CHECK
and
ZONE 09
messages to be displayed:
Communication between the panel and the receiver is interrupted.
or
No
valid
RF signals from at least one supervised wireless transmitter are received within
12 hours.
House Identification
If you are using a 5804BD, 5827, or 5827BD Wireless Keypad with the system, you must
program a House ID Code (01-31) in field
24 to establish proper communication, and the
keypad must be set to the same ID.
House ID 00 disables all wireless keypads.