Section 1 - Introduction
1–3
Optional VIP Module
The VISTA-15/VISTA-15CN supports the ADEMCO 4285/4286 VIP Module (refer to
Section 8: 4285/4286 VIP Module for further information).
Provides access to the system via on-premises or off-premises phones for arming, disarming,
etc., plus control of relay outputs and Powerline Carrier devices.
Paging Feature
If programmed, the paging feature allows certain system conditions to be reported to a pager.
Up to 16 digits may be programmed to be sent as a message to the pager. A 7-digit code
following the programmed message indicates the type of condition that has occurred.
Audio Alarm Verification (AAV) Option
Provides a programmable Audio Alarm Verification (AAV) option, which can be used in
conjunction with an output relay to permit voice dialog between an operator at the Central
Station and a person at the premises.
This AAV option must be used with a relay unit, such as an Eagle Model 1250.
U
L
The AAV option may not be used in UL installations.
Optional Long Range Radio
Allows all messages that have been programmed to go to the primary telephone number to
also be sent to any ECP-operational
ra
dio (such as the 7835C, 7720PLUS, and 7820) for
transmission to the Central Station.
Built-in Telephone Line Monitoring Option
You can monitor telephone line voltage to supervise the phone line connection. You must
connect the panel to a proper earth ground or you will get a false line cut indication if this
feature is enabled.
The loss of the line can optionally cause a local display, or a display and trouble sound.
Event Logging
Keeps a record of up to 48 selected events in a history log. All control and readout from the
log is done via ADEMCO COMPASS software
only
.
Quick Arm Feature
Quick Arm may be programmed , allowing use of the [#] key in place of the security code for
arming (Quick Arm will not work unless the Master code has been programmed into the
system).
Alarm Output Features
Provides a 12VDC, 2
amp
output that can drive the compatible sounders listed in
Section 9:
External Sounders
(assuming a fully charged battery is connected).
Steady output for burglary/panic, or
temporal
pulse output (3 pulses – pause – 3 pulses –
pause – 3 pulses . . .) for fire.
Uses
current
-limiting circuitry for protection.
• Provision for Bell supervision.
Optional Bell Supervision
Red jumper on control board, when cut, provides supervision of bell wiring (when bell is
wired with EOL resistor, as indicated in the instructions).