VISTA-15/VISTA-15CN Installation and Setup Guide
25–2
6128 REMOTE KEYPAD
1. Physical: 5-3/4” W x 4-3/4” H x 1” D (146mm x 121mm x 25mm)
2. Electrical:
Voltage Input: 12VDC; Current Drain: 30mA
3. Interface Wiring:
To control panel's keypad connection points.
RED:
GREEN:
YELLOW:
BLACK:
12VDC input (+) aux pwr
Data to Control Panel (DO)
Data from Control Panel (DI)
Ground
6128RF INTEGRATED KEYPAD
1. Physical: 5-3/4” W x 4-3/4” H x 1” D (146mm x 121mm x 25mm)
2. Electrical:
Standby: 90mA
Transmitting and/or relay activated: 120mA
Relay Contact: N/O, 1A, 28VDC
3. Interface Wiring:
Same as 6128 Remote Keypad above.
6139 REMOTE KEYPAD
1. Physical:
6-1/4” W x 4-3/4” H x 1” D (159mm x 121mm x 25mm)
2. Electrical:
Voltage Input: 12VDC; Current Drain: 100mA
3. Interface Wiring:
Same as 6128 Remote Keypad above.
5881/5882 SERIES RF RECEIVERS (5800 System)
1. Physical:
7-3/8” (187mm) W x 4-3/8” (111mm) H x 1-7/16” (37mm) D
Note:
10-7/8” (277mm) H with antenna
2. Electrical:
Voltage Input: 12VDC; Current Drain:
3. Interface Wiring:
To control panel's keypad connection points.
4. Range:
200ft (60m)
nominal
indoors from wireless transmitters (the
actual range to be determined with system in Test mode).
5. Zones:
(
With the
ADEMCO VISTA-15/VISTA-15CN
)
5881L/5882L: accepts up to 8 transmitters
5881M/5882M: accepts up to 16 transmitters
5881H/5882H: accepts up to 26 transmitters
5800TM TRANSMITTER MODULE (used with 5827BD Wireless 2-Way Keypad)
1. Physical:
2-1/4” W x 4-1/8” H x 7/8” D (57mm x 105mm x 22mm)
2. Electrical:
Voltage Input: 12VDC; Current Drain: 20mA
3. Interface Wiring:
To control panel's keypad connection points.
4204 RELAY MODULE
1. Physical:
6-1/2” W x 4-1/4” H x 1-1/4” D (169mm x 108mm x 32mm)
2. Electrical: Voltage Input: 12VDC; Current Drain:
15mA (Relays off)
180mA (Relays on)
3. Interface Wiring:
To control panel's keypad connection points.
4. Four Output Relays:
SPDT Contacts, Rating: 2A max at 28VDC/AC
4219 WIRED EXPANSION MODULE
1. Physical:
6-1/2” W x 4-1/4” H x 1-1/4” D (169mm x 108mm x 32mm)
2. Electrical:
Voltage Input: 12VDC; Current Drain: 35mA
3. Interface Wiring:
To control panel's keypad connection points.
4. 8 EOLR Loops (A–H):
Loop A can be set for fast (10-15mSec) response to an open.
Vue de la page 117