ADEMCO Security System VISTA-15CN Guide d'installation Page 103

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 132
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 102
Section 21 - System Communication
21–3
ADEMCO Contact ID Reporting
takes the following format:
CCCC Q EEE ZZZ
where:
CCCC = Customer (subscriber) ID
Q = Event qualifier, where: E = new event, R = restore
EEE = Event code (3 hexadecimal digits)
NOTE:
For a complete list of event codes, refer to the Central Station
office receiver manual.
ZZZ = Zone/Contact ID number reporting the alarm, or user number for open/close
reports. System status messages (AC Loss, Walk Test, etc.) contain zeroes
in the ZZZ location.
TABLE OF CONTACT ID EVENT
CODES
Code Definition
110 Fire Alarm
121 Duress
122 Alarm, 24-Hour Silent
123 Alarm, 24-Hour Audible
131 Alarm, Perimeter
132 Alarm, Interior
134 Alarm, Entry/Exit
135 Alarm, Day/Night
143 Alarm, Expansion Module
146 Silent Burglary
150 Alarm, 24-Hour Auxiliary, 24-Hour Monitor
301 AC Power
302 Low System Battery/Battery Test Fail
305 System Reset
321 Bell/Siren # 1 Trouble
333 Trouble or Tamper Expansion Module
344 RF Receiver Jam Detection
351 Telco Line Fault
353 Long Range Radio Trouble
373 Fire Loop Trouble
Code Definition
374 Exit Error Alarm
380 Global Trouble, Trouble Day/Night, Hard-
wired Short, Single expired Cross Zone
fault.
381 RF Supervision Trouble
383 RF Sensor Tamper
384 RF Sensor Low Battery
401 Arm/Disarm for AWAY or MAXIMUM
406 Cancel by User
407 Remote Arm/Disarm (Downloading)
408 Quick Arm AWAY/Max
441 Arm/Disarm for STAY/INSTANT/NIGHT-
STAY
570 Bypass
602 Periodic Test
606 AAV to Follow
607 System Test
623 Event Log 80% Full
629 1-1/3 Day No Event