62–
Relay Group
Relays may be grouped for common activation by
time driven events (commands 06-10--see Section
20:
SCHEDULING OPTIONS
for more information).
Enter 0 (no group) or 1-8 for a specific group
number. Press * to continue.
Restriction
1=yes 0=no
The system may have some devices which are not
intended to be under end user control, such as
relays activating fire doors or machinery. Enter 1 if
the end user will be restricted from accessing this
relay. Press * to continue.
Relay Type
Enter 1 for 4204 relay outputs. Enter 2 for Powerline
Carrier devices. Press * to continue.
ECP ADDRESS
For relay module (4204) outputs, enter the actual
relay module's address (01-15) as set by its DIP
switches.
MODULE RELAY #
For 4204 relay outputs, enter the specific relay
number on that module (1-4). Press * to continue.
House Code
For Powerline Carrier devices, enter the numerical
equivalent of the House Code of the device as
follows:
A=00 E=04 I=08 M=12
B=01 F=05 J=09 N=13
C=02 G=06 K=10 O=14
D=03 H=07 L=11 P=15
Unit Code
Enter the numberical unit code of the Powerline
Carrier device (00-15). Press * to continue.
The keypad will display the Start and Stop summary
screens again. Press * to continue.
5. When all relays have been programmed, enter 00 at the "ENTER RELAY NO."
prompt.
6. If defining a Zone List, continue to the next procedure in this section. If not,
enter 00 + * at the next two prompts. Then enter *99 to exit programming
completely. After exiting, enter the [Installer Code] + OFF to cancel the
system's settling delay.