ADEMCO Vista-50 Manuel d'utilisateur Page 177

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 196
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 176
– 165
To program that speed key sequence, type the following :
*2 D 61011 D 4D*1 D D
Note that the "D" key is pressed after the "2," the last "1" and the "4," separating
the different commands. Press "D" twice to complete the entry and exit.
To execute a speed key sequence, press the "D" key. The following appears:
ENTER USER CODE
****
Enter your user code. The programmed speedkey sequence will begin
automatically.
When defining speedkey sequences, do not use the [#] key to represent Quick
Arming. The system uses the code entered in response to the prompt to initiate
commands in a speedkey sequence, so the quick arm key is unnecessary. The
system interprets the use of the [#] key in a speedkey sequence as its designated
function only (e.g. #2 is not interpreted as arm in away mode, but rather as enter
house ID sniffer mode).
Manual Relay Activation Mode (#70 Mode)
The system allows users to manually activate relays/X-10 modules by keypad
command using either the keypad or a telephone keypad (if VIP module is used).
The user will be prompted (either by keypad alpha display or telephone voice
module).
To activate relays from a keypad, enter 4-digit security code + [#] +70.
To activate relays using a telephone and VIP module, first dial the 2-digit phone
access code. When the system acknowledges the access, enter 4-digit security
code + [#] + 70. The following prompts/voice responses will begin.
ENTER DEVICE NO.
00=QUIT 01
Voice: "ENTER DEVICE CODE NOW"
Enter the 2-digit number of the relay/X-10 module to be
activated.
nn DEVICE IS OFF
HIT 0=OFF , 1=ON
Voice: "
voice descriptor
DEVICE nn ON/OFF. FOR
voice descriptor
ON ENTER 1, FOR
voice descriptor
OFF ENTER 0"
Press 0 or 1 to turn the device off or on respectively.
"nn" represents the 2-digit relay/X-10 module number
and
voice descriptor
is the relay voice descriptor
programmed by the installer (see relay descriptor
programming section).
nn DEVICE IS OFF
HIT THE "*" KEY
Voice: "
voice descriptor
DEVICE nn ON/OFF. TO EXIT
ENTER 00 NOW"
From a keypad, press * to continue. The ENTER
DEVICE NO. prompt will appear.
From a telephone keypad, enter 00 to exit, or enter the
next relay number to be programmed. The current on/off
state of that relay will be annunciated as described
above. Alternatively, if 6 seconds elapses with no key
depression, the voice module will annunciate the
"ENTER DEVICE CODE NOW" message.
Vue de la page 176
1 2 ... 172 173 174 175 176 177 178 179 180 181 182 ... 195 196

Commentaires sur ces manuels

Pas de commentaire