*15 KEYSWITCH ASSIGNMENT
Enter the partition number 1-8 in which the keyswitch is being used;
otherwise, enter 0.
Requires the use of zone 7 wired loop (zone 7 no longer available as
protection zone when used for keyswitch operation). If the keyswitch is
used, the fire and panic alarm voltage triggers automatically become
ARMING and READY status outputs for support of the Keyswitch LEDs.
Note: Zone type 10 is automatically assigned to zone 7 if a keyswitch is
used. Reports openings/closing by user "0" if reporting is enabled in field
*40.
*16 CONFIRMATION OF ARMING DING (partition-specific)
Enter 1 to enable 1/2 second external alarm sounding ("ding") at the end
of exit delay (or after kisoff from the central station, if sending closing
reports.) Otherwise enter 0.
*17 AC LOSS KEYPAD SOUNDING
Enter 1 to enable sounding at the keypad (rapid beeping) when AC
power is lost (sounding occurs about 2 minutes after actual AC loss).
Enter 0 if no AC power loss keypad sounding is desired.
*18 AC LOSS SIREN
Enter 1 to enable the external alarm sound after AC power has been out
for 4 hours; Otherwise enter 0 (no alarm). (Must be "1" for UL)
*19 RANDOMIZE AC LOSS REPORT
Selecting this option helps prevent an overload of AC loss messages at
the central station during a community blackout.
Enter 1 to randomize AC loss reporting between 10-40 min. after an
actual AC loss. Enter 0 for normal AC loss reporting (about 2 minutes
after actual AC loss).
*20 VIP MODULE PHONE CODE
If a 4285 voice module is being used, enter the 2-digit phone code used
to access the system.
Enter 01-09 for first digit, and enter 11 (for *) or 12 (for #) for second digit.
To disable the voice module, enter 00 for the 1st digit and enter 11 for
the 2nd digit of the code (disable code = 00,11).
*21 PREVENT FIRE TIME-OUT
Enter 1 to disable (no timeout) the alarm sounder duration for any zone
designated as a fire zone, regardless of partition, so that fire sounding
continues until the system is reset.
Enter 0 if the normal burglary alarm sounder duration (programmed in
partition-specific field *13) should apply to fire alarms.
*22 KEYPAD PANIC ENABLES (partition-specific) | |
Enter 1 to enable the appropriate keypad panics used 95 96 99
in this partition. Otherwise enter 0.