ADEMCO Vista-50 Guide d'installation Page 99

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 112
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 98
C-1
APPENDIX C
Specifications
••••••••••••••••••••••••••••••••••••••••••••••••••
VISTA-50P/VISTA-50PUL CONTROL
Physical:
Standard Cabinet (included) 12 1/2" W x 14 1/2" H x 3" D
UL Cabinet (optional) 14 1/2" W x 18" H x 4.3" D (Included in the VISTA-ULKT kit)
Electrical:
Voltage Input: From 1361 Plug-In Transformer (use 1361CN in Canada) or 1361X10 transformer (for
X-10 installations) rated 16.5VAC, 40 VA.
Alarm Sounder Output: 10VDC-13.8VDC, 1.7 amps max. (UL1023, UL609 installations); 750mA less aux.
current draw (UL985 installations).
Auxiliary Power Output: 9.6VDC-13.8VDC, 750mA max. For UL installations, the accessories connected to the
output must be UL Listed, and rated to operate in the above voltage range.
Backup Battery: 12VDC, 4AH or 7AH gel cell. YUASA NP4-12 (12V, 4AH) or NP7-12 (12V, 7AH)
recommended.
Standby Time: 4 hours min. with 750mA aux. load using 7AH battery.
Circuit Protectors: PTC circuit breakers are used on battery input to protect against reverse battery
connections and on alarm sounder output to protect against wiring faults (shorts).
A solid-state circuit breaker is used on auxiliary power output to protect against wiring
faults (shorts).
Digital Communicator
Formats Supported: ADEMCO High Speed, ADEMCO 4 + 2 Express, ADEMCO Low Speed, ADEMCO
Contact ID, Sescoa and Radionics Low Speed
Line Seize: Double Pole
Ringer Equivalence: 0.7B
FCC Registration No.: AC398U-68192-AL-E
Remote Keypads
6139
Physical:
Width: 6.25 inches
Height: 4.75 inches
Depth: 1.25 inches
Electrical:
Voltage Input: 12VDC
Current Drain: 100mA
Interface Wiring:
RED: 12VDC input (+) auxiliary
power
BLUE: Not Used
GREEN: Data to control panel
YELLOW: Data from control panel
BLACK: Ground and (-) connection from
supplemental power supply
6160
Physical:
Width: 7.437 inches
Height: 5.25 inches
Depth: 1.312 inches
Electrical:
Voltage Input: 12VDC
Current Drain: 150mA
Interface Wiring:
RED: 12VDC input (+) auxiliary
power
BLUE: Not Used
GREEN: Data to control panel
YELLOW: Data from control panel
BLACK: Ground and (-) connection from
supplemental power supply
Vue de la page 98
1 2 ... 94 95 96 97 98 99 100 101 102 103 104 ... 111 112

Commentaires sur ces manuels

Pas de commentaire