VISTA-128FBP/VISTA-250FBP Installation and Setup Guide
5-4
FIELD TITLE and DATA ENTRIES EXPLANATION
*33
Primary Phone Number
Enter 0-9; #11 for *, #12 for #, #13 for a 2-
second pause.
Enter the primary central station phone number, up to 17 digits. This is the
phone number the control will use to transmit Alarm and status messages to
the central station. Do not fill unused spaces.
NOTE: Backup reporting is automatic only if a secondary phone number is
entered.
*34
Secondary Phone Number
Enter 0-9; #11 for *, #12 for #, #13 for a 2-
second pause.
Enter the secondary phone number, up to 17 digits. The secondary phone
number is used if communication on the primary number is unsuccessful, or if
split/dual reporting is desired. Do not fill unused spaces.
NOTE: If this field is programmed, a secondary subscriber account number
(field *90)
must
also be programmed.
*35
Download Phone Number
Enter 0-9; #11 for *, #12 for #, #13 for a 2-
second pause.
Enter the downloading phone number, up to 17 digits. Do not fill unused
spaces.
NOTE: This field is applicable only if downloading is utilized.
*36
Download ID Number
Make entries as 2-digit numbers as follows:
00=0 01=1 02=2 03=3 04=4 05=5
06=6 07=7 08=8 09=9 10=A 11=B
12=C 13=D 14=E 15=F
Enter eight digits.
NOTE: This field is applicable only if downloading is utilized.
*37
Download Command Enables
0 = disable
1 = enable
Enabling a function means that you are able to perform that function via the
ADEMCO Compass Downloading software.
Functions are as follows: Dialer Shutdown; System Shutdown; Not Used;
Remote Bypass; Remote Disarm; Remote Arm; Upload Program; Download
Program.
For Commercial Burglary and Fire installations, all entries must be 0.
*38
Prevent Zone XXX Bypass
(partition-specific)
Enter a zone number (001-250).
Enter 000 if all zones can be bypassed.
Enter three digits for zone that cannot be bypassed by the user.
NOTES:
The actions manual bypass, group bypass, auto-stay, and STAY/INSTANT
arming modes cannot bypass any zone programmed in this field.
The system will not arm if the zone is programmed with the vent zone or force
arm fault attributes.
*39
Enable Open/Close Report for
Installer Code (partition-specific)
0 = disable
1 = enable
If enabled, whenever the Installer Code is used to arm or disarm the partition,
an open/close report is sent to the central station.
*40
Enable Open/Close report for
Keyswitch
0 = disable
1 = enable
If enabled, whenever the keyswitch is used to arm or disarm the partition, an
open/close report is sent to the central station.
*41
Normally Closed or EOLR (Zones
3-8)
0 = EOLR supervision
1 = N.C. loops
If EOLR supervision is selected, end-of-line resistors must be used on zones
3-8.
If N.C. loops is selected, end-of-line resistors cannot be used and only
normally closed devices must be used.
Must be set to 0” for Commercial Fire and Burglary installations.
*42
Dial Tone Pause
Enter the wait time for dial tone detection:
0 = 5 seconds; 1 = 11 seconds; 2 = 30
seconds.
Enter the time the system waits for dial tone before dialing. Applies if true dial
tone is not selected in field *43.
Must be 0 for UL installations.
*43
Dial Tone Detection
0 = disable
1 = enable
If enabled, the system waits for true dial tone. If no dial tone is detected,
control dials at end of pause programmed in field *42.
If disabled, the system pauses for seconds entered in field *42, then dials.
NOTE: Disabling may be necessary in high-noise environment telco networks
where noise can be confused with dial tone, resulting in premature dialing.
Vue de la page 67
1 2 ... 63 64 65 66 67 68 69 70 71 72 73 ... 135 136

Commentaires sur ces manuels

Pas de commentaire

Seametrics WMP-Series manuali

Manuali dei proprietari e guide per l'utente per Apparecchiature Seametrics WMP-Series.
We fornisce 1 manuali pdf Seametrics WMP-Series per scaricare gratuitamente in base al tipo di documento: Manuale Utente






Più prodotti e manuali per Apparecchiature Seametrics

Modelli Tipo di Documento
AG2000 Manuale Utente   Seametrics AG2000 Manual del usuario, 4 pagine
iMAG-Series Manuale Utente   Seametrics iMAG-Series User Manual, 16 pagine
DL76 Manuale Utente   Seametrics DL76 User Manual, 4 pagine
FT400-Series Manuale Utente   Seametrics FT400-Series User Manual, 12 pagine
PT35 Manuale Utente   Seametrics PT35 User Manual, 4 pagine
RSP5 Manuale Utente   Seametrics RSP5 User Manual, 4 pagine
FT500-Series Manuale Utente   Seametrics FT500-Series User Manual, 8 pagine
PS40 Manuale Utente   Seametrics PS40 User Manual, 2 pagine
PD10 Manuale Utente   Seametrics PD10 User Manual, 4 pagine
PC-SERIES Manuale Utente   Seametrics PC-SERIES User Manual, 4 pagine
AD30 Manuale Utente   Seametrics AD30 User Manual, 2 pagine
FlowInspector Manuale Utente   Seametrics FlowInspector User Manual, 16 pagine
AG2000 v.2 Manuale Utente   Seametrics AG2000 v.2 User Manual, 4 pagine
AG2000 v.1 Manuale Utente   Seametrics AG2000 v.1 User Manual, 4 pagine
AG1000 Manuale Utente   Seametrics AG1000 User Manual, 10 pagine
AO45 Manuale Utente   Seametrics AO45 User Manual, 4 pagine
DL75 v.1 Manuale Utente   Seametrics DL75 v.1 User Manual, 4 pagine
EM 100-102 v.1 Manuale Utente   Seametrics EM 100-102 v.1 User Manual, 4 pagine
EM 100-102 v.2 Manuale Utente   Seametrics EM 100-102 v.2 User Manual, 4 pagine
EM 101 v.1 Manuale Utente   Seametrics EM 101 v.1 User Manual, 6 pagine