Page 1 - 9,67$&1

K3894V2 7/01 9,67$9,67$&16HF XULW\6\VWHP 3URJUDPPLQJ*XLGH •••••••••••••••••••*®

Page 2

– 10 – ✱81 ZONE LISTS FOR OUTPUT DEVICES (01 - 03); Cross Zones (04); and Night-Stay Zones (05). This is an interactive mode. Fill in the required

Page 3

– 11 – SPECIAL MESSAGES OC = OPEN CIRCUIT (no communication between console and control). EE or ENTRY ERROR = ERROR (invalid field number entered;

Page 4 - [15 15 15 15]

– 12 – ALPHA VOCABULARY LIST 000 (Word Space) A • 001 AIR • 002 ALARM 004 ALLEY 005 AMBUSH • 006 AREA • 007 APARTMENT • 009 ATTIC 010 AU

Page 5 - EXPANSION ZONES:

– 13 – ENROLLED TRANSMITTERS ZONE No. ZONE TYPE ZONE INPUT TYPE SERIAL No. (If applicable) Stick Serial No. Label from Transmitter Here LOOP No.

Page 6

– 14 – ENROLLED TRANSMITTERS (cont'd) ZONE No. ZONE TYPE ZONE INPUT TYPE SERIAL No. (If applicable) Stick Serial No. Label from Transmitter

Page 7

– 15 – AUX. POWEROUTPUT10.5-13.8VDC600mA MAX.(500mA MAX.FOR ULINSTALLATIONS)INTERRUPTSFOR 4-WIREFIRE ALARMRESET. ALLCIRCUITS AREPOWERLIMITED.NOT

Page 8

165 Eileen Way, Syosset, New York 11791 Copyright © 2000 PITTWAY CORPORATION ¬.9V

Page 9

– 2 –

Page 10

– 3 – Local programming requires the use of a 2-line alpha keypad connected to the keypad terminals on the control. Field Function [ ] = Defaul

Page 11

– 4 – DIALER PROGRAMMING (✱40 – ✱52) In fields ✱40, ✱41, ✱42, enter up to the number of digits shown. Do not fill unused spaces. Enter 0–9; # +11

Page 12 - CHARACTER (ASCII) CHART

– 5 – ✱56 / ✱58 ZONE ASSIGNMENT/ALARM REPORT CODES This field is an interactive mode. Fill in the required data on the worksheet below (and on next

Page 13

– 6 – EXPLANATION OF ZONE ASSIGNMENT TABLE HEADINGS Zn = ZONE NO. Zone Nos. are from 01 to 06, 09 to 35, 92, 95, 96, 99. Some are pre-assigned. Wi

Page 14

– 7 – RESTORE REPORT CODES (✱70 – ✱76) † ✱70 ALARM RESTORE RPT CODE [0] 2nd digit is automatically sent as the 2nd digit of the zone alarm rep

Page 15 - WARNING:

– 8 – DOWNLOAD INFORMATION (✱94, ✱95) ✱94 DOWNLOAD PHONE NO. | | | | | | | | | | | | | | | | |

Page 16 - ¬.9V

– 9 – OUTPUT RELAYS/POWERLINE CARRIER DEVICES WORKSHEET FOR ✱80 and ✱81. Applicable only if Relays and/or Powerline Carrier devices are to be used.