ADEMCO LYNXR24 Guide d'installation Page 1

Naviguer en ligne ou télécharger Guide d'installation pour Systèmes de contrôle d'accès de sécurité ADEMCO LYNXR24. ADEMCO LYNXR24 Setup guide Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 24
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 0
/<1;56HULHV
6HFXULW\6\VWHPV
3URJUDPPLQJ*XLGHIRU
/<1;5/<1;5DQG/<1;5(1
AWAY
OFF
STAY
AUX
®
K5965 5/01 Rev. B
®
Vue de la page 0
1 2 3 4 5 6 ... 23 24

Résumé du contenu

Page 1 - /<1;56HULHV

/<1;56HULHV6HFXULW\6\VWHPV 3URJUDPPLQJ*XLGHIRU/<1;5/<1;5DQG/<1;5(1 AWAYOFFSTAYAUX® K5965 5/01 Rev. B

Page 2 - 7$%/(2)&217(176

- 10 - Field Function Programmed Values [ ] = Table 1 Default Value ✱95 RING DETECT COUNT FOR DOWNLOADING/REMOTE PHONE CONTROL MODE [15] 0

Page 3 - DATA FIELDS

- 11 - *56 ENHANCED ZONE PROGRAMMING PROCEDURE Use this mode to program zone information. Press *56 while in programming mode. Notes: (1) Entering

Page 4

- 12 - * DELETE ZONE PARAMETERS 0 = Discard the delete request. 1 = Confirm the requested delete. If 00 is entered in the zone type, confirmation

Page 5

- 13 - *80 DEVICE PROGRAMMING Use this mode to program Powerline Carrier Devices or zone lists for Chime by Zone feature. Press *80 while in programm

Page 6

- 14 - *81 ZONE LISTS Use this mode to define zone lists for Powerline Carrier Devices and/or for the chime by zone feature. Press *81 while in progr

Page 7

- 15 - *83 ENHANCED SEQUENTIAL MODE Use this mode to enter transmitter serial numbers. Press *83 while in programming mode. % - ZONE NUMBER Ente

Page 8 - Example:

- 16 - *84 ASSIGN ZONE VOICE DESCRIPTORS Use this mode to assign voice descriptors for each zone. These are the descriptors that are announced when

Page 9

-17- *85 RECORD CUSTOM VOICE DESCRIPTORS Use this mode to record up to 5 custom voice descriptors for use with zone announcements. Press *85 while i

Page 10

- 18 - Zone No. Zone Alarm Report Input Loop Transmitter Vocabulary (A 01) Type (zt) Code in hex (rc) Type (I) No. (l) Serial Number Inde

Page 11 - 26-41 should be assigned as

- 19 - POWERLINE CARRIER DEVICES WORKSHEET FOR *80, and *81. Applicable only if Powerline Carrier Devices are to be used, or chime-by-zone feature is

Page 12

- 2 - 7$%/(2)&217(176 DATA FIELDS ...

Page 13

- 20 - ✱81 ZONE LISTS FOR OUTPUT DEVICES Fill in the required data on the worksheet below and follow the procedure in the installation manual as you

Page 14 - *81 ZONE LISTS

- 21 - SPECIAL MESSAGES EE = Data Entry Error (invalid field number entered while programming; re-enter valid field number). FC = Communication F

Page 15

-22- INCOMINGPHONELINETO HANDSETPHONELINEWARNING:TO PREVENTRISK OFSHOCKDISCONNECTTELEPHONELINE AT TELECOMJACK BEFORESERVICINGTHIS UNIT.WEEKLY TESTIN

Page 17 - ZONES ON CONTROL:

165 Eileen Way, Syosset, New York 11791 Copyright © 2001 PITTWAY CORPORATION i./lK5965 5/01

Page 18

- 3 - TO LOAD A DEFAULT SET: While in Program mode, press *97, then enter a number 1-4 corresponding to the default table desired. See the Installati

Page 19 - 80, and

- 4 - Field Function Programmed Values [ ] = Table 1 Default Values ZONE SOUNDS AND TIMING (✱ 31– ✱ 39) ✱31 SINGLE ALARM SOUNDING/ZONE † [0] 1

Page 20 - used or not

- 5 - Field Function Programmed Values [ ] = Table 1 Default Value ✱42 SECONDARY PHONE NUMBER

Page 21

- 6 - Field Function Programmed Values [ ] = Table 1 Default Value ✱49 SPLIT/DUAL REPORTING [0] 0 = Disable (Backup report only) TO PRI

Page 22 - POWERLINE

- 7 - Field Function Programmed Values [ ] = Table 1 Default Value TO PROGRAM SYSTEM STATUS, & RESTORE REPORT CODES (✱59–✱76, & ✱89):

Page 23

- 8 - ✱75 RF XMTR LO BAT RST RPT CODE | [1,0] ✱76 TEST RESTORE RPT CODE | [0,0] OUTPUT AND SYSTEM SETUP (*80–*92) ✱80

Page 24 - K5965 5/01 Rev. B B801

- 9 - Field Function Programmed Values[ ] = Table 1 Default Value ✱91 LYNXR/LYNXR24 LONG RANGE RADIO/ALARM AUDIO VERIFICATION (AAV)/REMOTE PHONE

Commentaires sur ces manuels

Pas de commentaire