- 4 -
Field Function
Programmed Values [ ] = Table 1 Default Values
ZONE SOUNDS AND TIMING (
✱
✱✱
✱
31–
✱
✱ ✱
✱
39)
✱
31
SINGLE ALARM SOUNDING/ZONE
†
[0]
1 = yes, limit once per arming period (also applies to long range radio
output if “0” is selected in *91 field); 0 = no limit
UL installations = 0
✱
32
FIRE SOUNDER TIMEOUT
†
[0]
0=timeout; 1=no timeout
✱
33
ALARM BELL TIMEOUT
†
[1]
0 = none; 1=4 min; 2=8 min; 3=12 min; 4 = 16 min
UL installations = 1 (4 min) minimum
✱
34
EXIT DELAY
|
†
[70]
00-99 = exit delay time (in seconds).
UL installations = 60 seconds max.
✱
35
ENTRY DELAY 1 (zone type 01)
|
†
[30]
00-99 = entry delay time (in seconds);
UL installations = 45 seconds max.
✱
36
ENTRY DELAY 2 (zone type 02)
|
†
[60]
00-99 = entry delay 2 time (in seconds);
UL installations = 45 seconds max.
✱
37
AUDIBLE EXIT WARNING /
QUICK EXIT
†
[1, 1]
Exit Warn Quick Exit
0 = no; 1 = yes
✱
38
CONFIRMATION OF ARMING DING
† [0]
0 = no; 1 = yes (when armed by self-contained keypad or RF)
2 = yes (when armed by RF keypad only).
✱
39
POWER UP IN PREVIOUS STATE
† [1]
0 = no; 1 = yes; UL installations = 1
†
Entering a number other than the one specified may give unpredictable results.
DIALER PROGRAMMING (
✱
40–
✱
53)
In fields
✱
40,
✱
41,
✱
42, enter up to the number of digits shown. Enter 0–9; #+11 for '*'; #+12 for '#'; #+13 for a
pause.
✱
40
PABX ACCESS CODE
Enter 6 digits. If fewer than 6 digits are entered, pressing *
advances to the next field. To clear entries from field, press *40*
NOTE:
Only a corporate installer can view/edit telephone numbers in Fields *41 and *42.
✱