- 21 -
MONITRONICS LYNXR-EN PROGRAMMED VALUES
The following table summarizes the values have been programmed into the Monitronics LYNXR-EN at the factory and
replace the Table 1 values that are shown in the Installation Guide. Loading any other default table will override these
programmed values.
Function Entry
Function Entry
*20 Installer code 4,1,1,2 *58 RF jam detection 0
*21 Quick arm enable 1 *59 Exit error report code 0
*22 Keypad backlight timeout 0 *60 Trouble report code 1,0
*23 Forced bypass 0 *61 Bypass report code 0,0
*24 RF house ID code 0,0 *62 AC loss report code 1,0
*25 Powerline carrier device house code 0 *63 Low battery report code 1,0
*26 Chime-by-zone 0 *64 Test report code 1,0
*27 Real-time clock display 1 *65 Open report code 0
*28 Not used --- *66 Arm away/stay report code 0,0
*29 Daylight saving time start/end month 4,10 *67 RF transmitter low battery report code 1,0
*30 Daylight saving time start/end weekend 1,5 *68 Cancel report code 0,0
*31 Single alarm sounding per zone 0 *69 Not used ---
*32 Fire sounder timeout 0 *70 Alarm restore report code 0
*33 Alarm bell timeout 1 *71 Trouble restore report code 1,0
*34 Exit delay 7,0 *72 Bypass restore report code 0,0
*35 Entry delay 1 (zone type 01) 3,0 *73 AC restore report code 1,0
*36 Entry delay 2 (zone type 02) 6,0 *74 Low battery restore report code 0,0
*37 Audible exit warning/quick exit 1,1 *75 RF transmitter low batt. restore report code 0,0
*38 Confirmation of arming ding 0 *76 Test restore report code 0,0
*39 Power up in previous state 1 *77 Not used ---
*40 PABX access code --- *78 Not used ---
*41 Standard phone number
Not viewable
*79 Not used ---
*42 Two way voice phone number
Not viewable
*80 Powerline carrier devices *80 table
*43 Standard subscriber account number 15,15,15,15 *81 Zone lists for devices *81 table
*44 Two way voice subscriber account number 15,15,15,15 *82 Not used ---
*45 Not used --- *83 Enhanced sequential mode *83 table
*46 End user telephone no. --- *84 Assign zone voice descriptor *84 table
*47 Phone system select 1 *85 Record custom voice descriptors *85 table
*48 Report format for Standard/Two-way 7,7 *86 Not used ---
*49 Central station/Pager reporting/Follow me 0 *87 Auxiliary function/ 1-button paging 0
*50 15 second dialer delay (burglary) 1 *88 Pager characters ---
*51 Periodic test report 3 *89 Event log 80% full report code 0,0
*52 First test report offset 3 *90 Event logging 15
*53 Sescoa/radionics select 0 *91 LRR/AAV/Remote Phone Control 4
*54 Lack of usage notification 0 *92 Number of reports in armed period 0
*55 Not used --- *93 Flexible call back 0
*56 Enhanced zone programming *56 table *94 Download phone number
1,8,0,0,6,8,2,1,6,9,0
*57 Not used --- *95 Ring detect count for downloading 15
Master User Code 1,2,3,4
Note:
The defaults shown for fields *90 and *94 also apply to Tables 2 - 4.
*56 ZONE ASSIGNMENT/ALARM REPORT CODES
Zone No. Zone Type Code Input Loop Descriptor
01 00 0,0 HW ---
02 01 1,0 3 (RF) 2 47,04 (FRONT DOOR)
03 01 1,0 3 (RF) 2 33,04 (BACK DOOR)
04 03 1,0 3 (RF) 2 80 (WINDOW)
05 10 1,0 3 (RF) 1 56 (MOTION DETECTOR)
26 21 1,0 5 (BR) 3
27 22 1,0 5 (BR) 2
28 20 1,0 5 (BR) 4
29 23 0,0 5 (BR) 1
30 21 1,0 5 (BR) 3
31 22 1,0 5 (BR) 2
32 20 1,0 5 (BR) 4
33 23 0,0 5 (BR) 1
92 --- 1,0 --- ---
95 09 1,0 --- ---
96 08 1,0 --- ---
99 07 1,0 --- ---
Notes:
1. Zone 1 is a hardwire zone; Zone 2 through 41 are RF zones; Zone 92 is Duress; Zones 95, 96 and 99 are keypad panic
2. The defaults shown for Zones 92 - 99 also apply to Tables 2 - 4.