-17-
*85 RECORD CUSTOM VOICE DESCRIPTORS
Use this mode to record up to 5 custom voice descriptors for use with zone announcements. Press *85 while in
programming mode.
NOTE:
Entry of a number other than one specified will give unpredictable results.
85
RECORD CUSTOM VOICE DESCRIPTORS
0 = Exit mode, upon which this prompt blinks.
1 = Enter mode
A 7
d
CUSTOM DESCRIPTOR NUMBER
Enter 7 +
d
, where d = 0-4, each representing custom word 70, 71, 72, 73 or 74 respectively. Existing
descriptor will be announced.
Press [8] + [#] to start recorder. Begin speaking immediately after the third beep.
Speak the desired word clearly near the keypad microphone. Recording stops after 1.5 seconds.
6 = Accept word and ready to record next descriptor (prompt A….7d)
[#] = Re-record descriptor
00 = Exit Record mode after pressing 6 (displays blinking 85; enter * + desired data field or menu mode
number)
Press any other key to repeat the recorded word.
✱
✱✱
✱
56 ENHANCED ZONE PROGRAMMING WORKSHEET
Fill in the required data on this worksheet, then follow the programming procedure in the Installation and Setup Guide.
ZONES ON CONTROL:
See explanation of headings (defaults shown are for Table 1)
Zone Zone Zone Alarm rpt code Vocabulary
Description No. (a 01) Type (zt) (hex) (rc) Index
Note: Zone 1 cannot be used as a fire zone.
Zone No. Zone Alarm Report Input Loop Transmitter Vocabulary
(A 01) Type (zt) Code in hex (rc) Type (I) No. (l) Serial Number Index
0|2
|
[01]
| | [01 00]
[3]
[2]
| |
[47-04-99]
0|3
| [01]
| | [01 00] [3] [2]
| | [33-04-99]
0|4 | [03] | | [01 00]
[3] [2]
| |
[80-99-99]
0|5 | [10] | | [01 00]
[3] [1]
| |
[56-99-99]
0|6 | | |
| |
0|7 | | |
| |
0|8 | | |
| |
0|9 | | |
| |
1|0 | | |
| |
1|1 | | |
| |
1|2 | | |
| |
1|3 | | |
| |
1|4 | | |
| |
1|5 | | |
| |
1|6 | | |
| |
Wired Zone 1
0 1
[00]
[00 00]
I I
Duress
9 2
[01 00]
I I
Keypad Panic (1 &
✱
)
9 5
[09]
[01 00]
I I
Keypad Panic (3 & #)
9 6
[08]
[01 00]
I I
Keypad Panic (
✱
& #)
9 9
[06]
[01 00]
I I
Commentaires sur ces manuels