ZONE LISTS FOR OUTPUT DEVICES
Fill in the required data on the worksheet below and follow the procedure in the installation manual as you enter the data
during the displays and prompts that appear in sequence.
Note:
Record desired zone numbers below. More or fewer boxes than shown may be needed, since any list may include
any
or
all
of a system's zone numbers.
Zone List 1
: Started or stopped by zone numbers (enter 00 to end entries).
.etc. [28][32]
Zone List 2
: Started or stopped by zone numbers (enter 00 to end entries).
.etc. [29][33]
Zone List 3
: Started or stopped by zone numbers AND/OR assignment of Chime zones (enter 00 to end entries)
.etc.[02][03]
5800 SERIES LOOP NUMBERS
LOOP 1
5806/5807/5808/5808LST
ENROLL AS
"RF"
5804WATCH
LOOP 1
5809
ENROLL AS
"RF"
5818
ENROLL AS
"RF"
LOOP 1
5849
ENROLL AS
"RF"
LOOP 1
(SOUND)
5802 MN2
ENROLL AS
"UR" OR "RF"
LOOP
1
5850 (GBD)
ENROLL AS
"RF"
(Green)
(Red)
(Yellow)
LOOP 1
5814
ENROLL AS
"RF"
01009-012-V1
LOOP 1
(MOTION)
5890/5890PI
ENROLL AS
"RF"
LOOP
1
5802 MN
ENROLL AS
"UR" OR "RF"
5804BD/5804BDV
ENROLL AS
"BR"
PROGRAM HOUSE ID
LOOP 4
YOU MUST
ENROLL
THIS BUTTON
LOOP 3
LOOP 1
LOOP 2
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
5804/5804E
ENROLL AS "BR"
LOOP 1
LOOP 2
LOOP 4
YOU MUST
ENROLL
THIS
BUTTON
O
FF
LOOP 3
O
N
5816TEMP
ENROLL AS
"RF"
LOOP 1
(TEMP
SENSOR)
5817
ENROLL AS
"RF"
LOOP 2
(AUX.
CENTER)
LOOP 1
(PRIMARY)
LOOP 3
(AUX.
RIGHT)
5816
ENROLL AS
"RF"
LOOP 1
(TERMINALS)
LOOP 2
(REED)
5816MN
ENROLL AS
"RF"
LOOP 1
(TERMINALS)
ALTERNATE
POSITION
FOR LOOP 2
LOOP 2
(REED)
LOOP 3
(TERMINALS)
5819S (WHS & BRS)
ENROLL AS
"RF"
LOOP 1
(INTERNAL
SHOCK
SENSOR
LOOP 2
(REED)
5819
ENROLL AS
"RF"
LOOP 2
(REED)
LOOP 3
(TERMINALS)
LOOP 1
(TERMINALS)
5827
PROGRAM
HOUSE ID
1
2
3
4
5
6
7
8
9
0
*
#
5800RL
SET
HOUSE ID
5801
ENROLL AS
"UR" OR "RF"
LOOP 3
LOOP 1
LOOP 2
LOOP 4
YOU MUST
ENROLL
THIS
BUTTON
LOOP 1
LOOP 2
LOOP 4
YOU MUST
ENROLL
THIS
BUTTON
LOOP 3
Note: You must enroll loop 4 on the 5801, 5804/5804E, 5804BD/5804BDV and 5804WATCH transmitters, regardless of whether it is
used or not.
U
L
The 5800RL, 5802MN, 5802MN2, 5804, 5804BD, 5804BDV, 5804E, 5804WATCH, 5808LST, 5814, 5816TEMP,
5819, 5819S(WHS & BRS), and 5850(GBD) transmitters are not intended for any UL installations.
SPECIAL MESSAGES
EE
= Data Entry Error (invalid field number entered while programming; re-enter valid field number).
FC
= Communication Failure
EA
= Exit Alarm
CA
= Cancel Alarm
CC
= Modem Communication (system is in communication with the central station)
dI
= Displayed approximately 4 seconds after powering up. This will revert to the Real-time Clock in approximately 1 minute and the green
“READY” LED should light. To bypass this delay, press: [#] + [0]. If “
dI
” remains displayed for more than one minute the system is
disabled.
PC
= Remote phone control feature is active
PH =
Speaker phone mode feature is active
90
= RF Jam