SECTION 12
J7 Trigger Outputs
•••••••••••••••••••••••••••••••••••••••••••••••••
In This Section
♦
General Information
♦
Ground Start Trigger Setup
♦
Remote Keypad Sounder Operation and Wiring
♦
Remote Keyswitch Operation and Wiring
♦
Audio Alarm Verification (AAV) Equipment
♦
Auxiliary Alarm Signaling Equipment
♦
Event Log Printer Connections
♦
Direct Wire Downloading
•••••••••••••••••••••••••••••••••••••••••••••••••
General Information
The J7 connector, located in the upper right-hand corner of the main PCB, provides 1 input
(labeled INPUT 1) and seven trigger outputs (labeled OUT 1 - OUT 7) that can be used to
interface to the following:
• Ground start module
• Remote keypad sounder
• UL Listed keyswitch
• Audio alarm verification device (two-way voice)
• Auxiliary alarm signaling equipment such as an ADEMCO Long Range Subscriber Radio
• Event logging serial printer (via the 4100SM Interface Module)
• PC computer used to direct-wire download the panel's programming information (via the
4100SM Interface Module)
The trigger output ratings are listed below. Note that all outputs are power-limited.
Outputs 1, 5, 7: LOW: 2K to ground
HIGH: 10-14 VDC @ 20 mA max
Remaining Outputs: LOW: 1K to ground
HIGH: 10-14 VDC through 5K
The pin assignments for the J7 connector are shown in
Figure 12-1
. Use a 4142TR 9-wire
trigger cable (1 supplied) to interface with this connector. The panel does not supervise field
wiring connected to this connector.