VISTA-128B Installation Instructions
1-4
• Can be programmed to activate using time intervals
• Can be used for style-Y supervised bell outputs (4204CF only)
• Can be activated manually using the #70 Relay Command Mode
• Can be supervised by control panel (zones 601-632)
• Can each have an alpha descriptor assigned to it
Optional Vista Interactive Phone Module
Supports the ADEMCO 4285/4286 VIP Module. This permits access to the security system to
do the following:
• Obtain system status information
• Arm and disarm security system
• Control relays
U
L
The 4285/4286 VIP Module is not Listed for use with the VISTA-128B Control Panel in a UL
commercial installation
.
Access Control
If programmed, provides users with a command which activates relays to open access doors
(e.g., lobby door), to turn on lights, etc. Each partition can be assigned any number of access
control relays, up to 32 for the system.
By using the Vista Gateway Module (VGM), the control can be connected to the ADEMCO
PassPoint system for a fully integrated access control system.
U
L
The access control function is not Listed for use with the VISTA-128B Control Panel in a UL
commercial installation
.
Optional Keyswitch
Supports the ADEMCO 4146 Keyswitch on any one of the system's 8 partitions. If used, zone
7 is no longer available as a protection zone.
Voltage Triggers
Provides a trigger connector whose pins change state for different conditions. Used with
LRR (Long Range Radio) equipment or other devices such as a remote keypad sounder,
keyswitch ARMED and READY LEDs, or a printer to print the system's event log.
Event Log
Keeps a log of different event types (enabled in programming). The event log has the
following characteristics:
• Stores up to 224 events
• Can be viewed at the keypad or through the use of V-LINK or Compass software
• Can be printed on a serial printer using a 4100SM Module including zone alpha
descriptors
• Can store PassPoint events
• Printed events can be sent to an alpha numeric pager