VISTA-128B Installation Instructions
23-8
010 INPUT S/N
Axxx-xxxx
This prompt is displayed if 1 (YES) is entered in response to
the "LEARN S/N?" prompt. The serial number may be enrolled
by one of two methods:
a) Enter the 7-digit serial number printed on the device
using an alpha keypad.
or
b) Activate the device by faulting or restoring the input you
wish to use for that zone (e.g., press a button, open or
close a door, etc.).
010 INPUT S/N
A022-4064
The system will enroll the serial number of the first device
heard.
If the serial and loop number combination is already present in the system, the keypad will sound
a single long beep and display the word "DUPLICATE" along with the serial number, and the
number of the zone containing the serial/loop number combination.
The system will then enter an optional confirmation mode so that the operation of the actual
programmed input can be confirmed. Activate the loop input or button that corresponds to
this zone. We recommend that you confirm the programming of every device before
proceeding to the next zone.
010 CONFIRM RF:1
A022-4064 1
When the system sees activity on the appropriate input, it will
beep three times and display the confirmation message.
At any time during this step, you may press the
[*]
key on the keypad or the upper left-hand
button of the program tool if you are satisfied with the serial and loop number combination that has
been enrolled, regardless of whether or not the enrolled input has been "confirmed."
If the incorrect device has been enrolled, press the [#] key on the keypad or upper right-hand
button on the program tool to delete the serial number and return to the "LEARN S/N" prompt. A
single long beep will be heard from the keypad to verify pressing of the upper right-hand button.
Then, press
1
(Yes) or press the upper left-hand button of the program tool (a single short beep
will verify the system is ready for enrolling) and re-activate the proper device loop input.
010 ZT P RC B INL
s 03 2 3C 0 RF1
The summary screen for the zone will appear. Note that an "s"
indicates that a serial number has, in fact, been enrolled. Press
[*] to accept the zone information.
If you want to delete the serial number, press [#]. This will
bring you back to the “INPUT TYPE” prompt. Press [*] to
change input type, loop number, and serial number.
When you have finished programming all zones, test each using the system's Test Mode. Do not
use the Transmitter ID Sniffer Mode for this, as it will only check for transmission of one zone on a
particular transmitter, NOT the zones assigned to each additional loop, and will not verify polling
loop type zones.