Section 17 – 4100APG Pager Interface
17-3
With the Event Log Printer
The VISTA-128B will support the 4100APG and serial printer. See Figure 17-2.
The serial printer must be configured for 1200 baud rate, seven data bits, even parity, and one stop
bit. (7/E/1).
J8
Brown
Violet
4100SM
8
7
6
5
4
3
2
1
4100APG
DB-25
DB-9
RJ-11
To Telco
6 7
Aux. Pwr
Aux. Gnd
Red
Black
RxD
TxD
Serial Port Input
Line
DB-25
1200 Baud Serial
Printer 7-E-1
Figure 17-2: Wiring the 4100APG With the Serial Printer
When you complete the module's mounting and wiring, you should install the module's cover
(with label affixed, as indicated next).
Programming the Control for the Pager
•
In field *64 enter 1 to enable the 4100APG pager interface.
•
In field *65 enter the phone number of the paging service for Alarm reports. Up to 17
digits may be entered.
•
In field *66 enter the Pager ID number of the paging service for Alarm reports. This is
the PIN number. Up to 10 digits may be entered.
•
In field *67 enter the phone number of the paging service for Trouble reports. Up to 17
digits may be entered.
•
In field *68 enter the Pager ID number of the paging service for Trouble reports. This is
the PIN number. Up to 10 digits may be entered.