Partition-Specific Fields
(Duplicate this page for each partition in the installation.)
To program these fields,
1. Press *91 to select a partition.
2. Enter a partition-specific field number (ex. *09).
3. Make the required entry.
4. Repeat steps 1-3 for each partition in the system.
PARTITION #____ PROGRAM FIELDS
1st Page Fields
*09
ENTRY DELAY #1 [02]
|
00-15 times 15 seconds. Maximum 03 for UL Listed
installations.
*10
EXIT DELAY #1 [03]
|
00-15 times 15 seconds. Maximum 04 for UL Listed
installations.
*11
ENTRY DELAY #2 [06]
|
00-15 times 15 seconds. Maximum 03 for UL Commercial
Burglary installations.
*12
EXIT DELAY #2 [08]
|
00-15 times 15 seconds. Maximum 04 for UL Commercial
Burglary installations.
*13
BELL 1 TIMEOUT [04]
|
01-15 times 2 minutes. Minimum 16 minutes for UL.
Commercial Burglary and 6 minutes for Commercial Fire
installations.
*16
CONFIRMATION OF ARMING DING [0]
1=enable; 0=disable. Must be "1" for UL Commercial
Burglary installations.
*22
KEYPAD PANIC ENABLES [001]
1=enable; 0=disable
995 996 999
*23
MULTIPLE ALARMS [1]
1=yes; 0=no. Enter 1 for Commercial Fire & UL Commercial
Burglary installations.
*29
QUICK ARM [1]
1=yes; 0=no
*32
PRIM. SUBS. ACCT #
| | | |
Enter 00-09; B-F (11-15) [15 15 15 15]
*38
PREVENT ZONE XXX BYPASS [000]
| |
001-128; 000 if all zones can be bypassed
*39
ENABLE OPEN/CLOSE REPORT [1]
FOR INSTALLER CODE
1=enable; 0=disable
*84
SWINGER SUPPRESSION [03]
|
01-15 alarms; Must be "00" (disabled) for Commercial Fire &
UL installations..
*85
ENABLE DIALER REPORTS[0]
FOR PANICS & DURESS
995 996 999 Duress
1=enable; 0=disable
*87
ENTRY WARNING [0]
1=continuous; 0=3 beeps
*88
BURG. ALARM COMM. DELAY [0]
|
1=16 seconds; 0=no delay. Must be "0" for UL Commercial
Burglary installations.
*90
SEC. SUBS. ACCT #
| | | |
Enter 00-09; B-F (11-15) [15 15 15 15]
1*18
AFFECTS LOBBY [0]
Enter 1 if this partition affects the common lobby; enter 0 if it
does not.
1*19
ARMS LOBBY [0]
Enter 1 if arming this partition attempts to arm lobby; enter 0
if it does not
2nd Page Fields
1*26
PANIC BUTTON OR SPEEDKEY
[00, 00, 00, 00]
|
|
|
|
A B C D
Enter speedkey macro # (01-35) to use keys A-C for macro.
Otherwise enter 00 to use as panic. For D key, enter macro
# or 00 to select macro when key is pressed.
1*43
PERM. KEYPAD BACKLIGHT [0]
1=enable; 0=disable When disabled, display lights when
any key is pressed, and turns off after period of keypad
inactivity.
1*45
EXIT DELAY SOUNDING [0]
1=enable; 0=disable Produces quick beeping during exit
delay if enabled.
1*47
CHIME ON BELL 1 [0]
1=enable; 0=disable
1*52
SEND CANCEL IF ALARM + OFF [0]
1=no restriction; 0=within Bell Timeout period only
1*76
ACCESS CONTROL RELAY FOR PART.[00]
|
Relay will be pulsed for 2 seconds whenever code + [0] is
pressed. Enter 00-16; 00=none. Must be "00" for
Commercial Fire & UL.