71–
Section 23. TROUBLESHOOTING GUIDE
SYSTEM
SYMPTOM POSSIBLE CAUSE REMEDY
1. Low Battery message on
keypad.
1. "Bat" or “System Lo Bat” (no zone Nos.)
1. System battery is low or missing.
2. Periodic beep(s) from
keypad.
2. System is in TEST mode.
2. Enter "Code" + OFF to exit TEST
mode.
3. Nuisance or phantom
alarm.
3. Sensors not properly installed, wired, or
monitored.
3. Check installation to see if in
accordance with established
procedure.
4. Intrusion alarm for no
apparent reason.
4a. Protected door or window opened while
system armed.
4b. Improper user operation of exit/entry
delays.
4c. Magnets located too far from switches,
and/or doors and windows not properly
aligned.
4a. Check with all occupants of protected
home.
4b. Check setting of entry and exit delays
.
4c. Check all openings for proper switch
and magnet orientation.
5. ÒCHECKÓ and zone number
2Ð8 is displayed.
5. Control has sensed a high resistance
condition on a loop in one of the hard-
wired zones (2–8).
5. Check the sensor or the loop wiring in
the affected zone. The system will not
arm until this condition is corrected (or
the affected zone is bypassed).
CONTROL
SYMPTOM POSSIBLE CAUSE REMEDY
1. "AC POWER" light off. 1a. Interrupted AC power supply. 1a. Check transformer connection and
Powerline circuit breaker.
2. Digital communicator
message not being
received.
2a. VISTA-20HWSE in TEST mode.
2b. Telephone connection not secure.
2c. Digital communicator malfunctioning.
2d. Telephone number in program needs
prefix or access code.
2e. Telephone call to central monitoring
station requires operator assistance.
2a. Remove from TEST mode.
2b. Check all connections.
2c. Check with a different VISTA-
20HWSE.
2d. Program prefix or access code into the
VISTA-20HWSE.
2e. VISTA-20HWSE system cannot work
in this situation.
3. Does not arm properly. 3a. Ready light not on. 3a. Check for faulted zones and make
intact, or use Bypass arming, if
desired.
4. VISTA-20HWSE doesn't
respond to keystrokes on
keypad.
4a. "CC" or "MODEM COMM" displayed.
4b. "d1" or "System Busy" displayed.
4c. Keypad address setting incorrect.
4a. System is in communication with
downloader at central station. Wait
until download session is finished.
4b. System has just been powered and is
in its one minute initialization. To
bypass this time, press '#' + '0'.
4c. Keypads must be set for address 31
(non-addressable mode).
SMOKE DETECTOR
SYMPTOM POSSIBLE CAUSE REMEDY
1. Detector alarms, no
apparent reason.
1a. Dust, dirt in sensing chamber.
1b. Improper location.
1c. Unit malfunctioning.
1a. Clean unit's sensing chamber with
vacuum cleaner per unit's instructions.
1b. See unit's instructions for locations to
avoid. Relocate as necessary.
1c. Replace detector.
2. Detector's siren sounds. 2a. Unit not receiving required power.
2b. Unit malfunctioning.
2a. Check for proper installation of
battery. Try new battery.
2b. Replace detector.