Field Function
Programmed Values [ ] = Table 1 Default Value
TO PROGRAM SYSTEM STATUS, & RESTORE REPORT CODES (
59–
76, &
89):
With a 3+1 or 4+1 Standard Format: Enter a code in the first box: 1–9, 0, B, C, D, E, or F. Enter "#+10" for 0, "#+11" for
B, "#+12" for C, "#+13" for D, "#+14" for E, "#+15" for F.
A "0" (not "#+10") in the first box will disable a report.
A "0" (not "#+10") in the second box will result in automatic advance to the next field when programming.
With an Expanded or 4+2 Format: Enter codes in both boxes (1st and 2nd digits) for 1–9, 0, or B–F, as described above.
A "0" (not "#+10") in the second box will eliminate the expanded message for that report.
A "0" (not "#+10") in both boxes will disable the report.
With Ademco Contact ID Reporting: Enter any digit (other than "0") in the first box, to enable zone to report (entries in the
second boxes will be ignored).
A "0" (not "#+10") in the first box will disable the report.
Examples: For Code 3 (single digit), enter: 3 | 0
For Code 3 2 (two digits), enter: 3 | 2
For Code B 2 (Hexadecimal), enter: #+11 | 2
SYSTEM STATUS REPORT CODES (
59–
68)
59
EXIT ERROR REPORT CODE
[1]
60 TROUBLE REPORT CODE
|
[1,0]
61 BYPASS REPORT CODE
|
[0,0]
62 AC LOSS REPORT CODE
|
[0,0]
63 LOW BAT REPORT CODE
|
[1,0]
64 TEST REPORT CODE
|
[1,0]
65 OPEN REPORT CODE
†† [0]
66 ARM AWAY/STAY RPT CODE
†† [0,0]
AWAY STAY
67 RF XMTR LOW BAT REPORT CODE
|
[1,0]
68 CANCEL REPORT CODE
|
[1,0]
RESTORE REPORT CODES (
70–
76)
70 ALARM RESTORE RPT CODE
[1]
71 TROUBLE RESTORE RPT CODE
|
[1,0]
72 BYPASS RESTORE RPT CODE
|
[0,0]
73 AC RESTORE RPT CODE
| [0,0]
74 LOW BAT RESTORE RPT CODE
|
[1,0]
(
††
2nd digit is automatically sent as the user
number if expanded or 4+2 reporting is
selected.)
2nd digit is automatically sent as 2nd digit of the zone alarm
report code programmed in
56, if expanded or 4+2 reporting
is
selected.
2nd digit is automatically sent as 2nd digit of the zone alarm
report code programmed in
56, if expanded or 4+2 reporting
is
selected.