- 2 -
TABLE OF CONTENTS
Data Fields .................................................................................................................................................................................3
56 Enhanced Zone Programming ......................................................................................................................................... 11
80 Device Programming ........................................................................................................................................................13
81 Zone Lists ......................................................................................................................................................................... 14
83 Enhanced Sequential Mode ............................................................................................................................................ 15
84 Assign Zone Voice Descriptors.........................................................................................................................................16
Vocabulary Index (for
84 Assign Zone Voice Descriptors) ....................................................................................................16
85 Record Custom Voice Descriptors ................................................................................................................................... 18
56 Enhanced Zone Programming Worksheet ....................................................................................................................... 18
Powerline Carrier Device Worksheet for
80 And
81 ............................................................................................................ 20
5800 Series Transmitter Loop Numbers Diagram.................................................................................................................... 21
Special Messages .................................................................................................................................................................... 21
LYNXR-I Summary of Connections Diagram............................................................................................................................ 22
Refer to the Installation and Setup Guide for detailed information on programming the LYNXR-I system. The
Installation and Setup Guide includes full descriptions of all data fields.
U
L
LYNXR-I is not intended for UL985 Household Fire applications unless a 24-hour backup battery (P/N
LYNXRCHKIT-HC or LYNXRCHKIT-SHA) is installed.
TO ENTER PROGRAMMING MODE:
1. Power up, then depress [
] and [#] both at once, within 50 seconds of powering up.
OR
2. For factory defaulted system, enter: Installer Code (4 + 1 + 1 + 2) plus 8 + 0 + 0. OR
If different Installer Code is programmed, enter: New Installer Code + 8 + 0 + 0.
(if
98 was used to exit previously, method 1 above must be used to enter the program mode again)
3. Upon entry into Program mode, data field
20 will be displayed (the first data field in the system) and
both keypad LEDs will flash.
TO PROGRAM THE DATA FIELDS:
1. Press [
] followed by the desired field number (e.g.,
21), then make the required entry.
2. The keypad beeps three times after entering data, then displays the next data field in sequence.
3. For phone number and account number fields, press [
] to end the entry if less than number maximum
number of digits is entered.
4. To delete an entry, simply press [
] plus that field number and reenter the correct data. For phone
number and account number fields
40-
44,
88 and
94, press [
] + field number + [
].
INTERACTIVE MENU MODES:
There are six interactive menu modes as listed below. To enter these modes, first enter Program mode. While in
Program mode, press [
] plus the mode number desired (e.g.,
56).
56 Enhanced Zone Programming............For programming zone characteristics, report codes, etc.
80 Device Programming...........................For programming Powerline Carrier Devices
81 Zone List Programming.......................For programming zone lists for use with Powerline Carrier Devices
83 Enhanced Sequential Mode................For entering transmitter serial numbers
84 Assign Zone Voice Descriptors ...........For assigning voice descriptors to zones
85 Record Custom Voice Descriptors......For recording custom voice descriptors