Applications
The VISTA-128FBP control is well
suited for a variety of applications
as an integrated fire and burglary
control. A diverse line of ADEMCO
initiating devices supports this
extremely powerful control. Some of
the applications supported are:
medical and professional buildings,
churches or synagogues, office
buildings, schools, strip malls,
larger residences and factory or
warehouse environments.
Installation
The VISTA-128FBP alarm system
has been designed to mount both
quickly and easily. It meets all
applicable requirements for UL
commercial fire and burglary
installations.
Specifications Electrical
• Primary power: 18VAC @ 72VA
ADEMCO No. 1451
• Control panel quiescent current
draw: 350mA
• Backup battery:
– 12VDC, 12AH min to 34.4AH
max
– Lead acid battery (gel type)
• Alarm power: 12VDC, 1.7A max
for each notification (bell) circuit
output Total 2.3amps @ 12V
• Aux. standby pwr: 12VDC, 1A
max
• Total power: 2.3A at 12VDC, 3.4A
at 24VDC from all sources
• Standby time: 24 hours with 1A
standby load using 34.4AH
battery
• Fusing: Battery input, aux. and
notification (bell) circuit outputs
are protected using PTC circuit
protectors. All outputs are power
limited.
• Optional 24-volt power supply, PS
24 Supplies two 24 VFW, 1.7A full
wave rectified, unfiltered
outputsMain Dialer:
• Line seize: Double Pole
• Ringer equiv.: 0.7B
• Formats: ADEMCO Low Speed,
ADEMCO 4+2 Express, ADEMCO
High Speed, ADEMCO Contact
ID, Sescoa and Radionics
• Dual phone line capability (using
5140DLM module)
Cabinet dimensions
• 18”H X 14.5”W X 4.3”D
Environmental
• Storage temp: -10°C to 70°C
• Operating temp: 0°C to 50°C
• Humidity: 85% RH
• EMI: Meets or exceeds the
following requirements:
– FCC Part 15, Class B Device
– FCC Part 68
– IEC EMC Directive
Agency Listings Burglary
• UL609 Grade A Local Mercantile
Premises and Mercantile Safe and
Vault
• UL611/1610 Grades A, AA,
Central Station
• UL365 Grades A, AA Police
Connect
Fire
• UL864/NFPA72 Local, Central
Station and Remote Station
• Factory Mutual
• California State Fire Marshal
• MEA
• UL985
Notification
Appliance
5881
Wireless Receiver
(Max Two)
6139R
32 Character
Red-Alpha
Keypad
4204CF
Supervised
NAC
Module
4293SN
V-Plex Adapter
4944SN
Addressable
Recessed Mount
Contact
Supports Up To 16
Conventional 2-Wire
Smoke Detectors
Supports Up To 64
Conventional 2-Wire
Smoke Detectors
4209U
Group Zoning
Module
V-Plex
Two-Zone
expander
4190SN
V-Plex Two-Zone
Expander
4193SN
Serial Interface
Module
4297
Isolation/
Extender Module
4190SN
5140MPS - 1*
5140MPS - 2*
Manual Pull Stations
Tamper Switch*
Flow Switch*
Low Temp Switch*
5808LST
Smoke
Detectors
5808LST
Smoke
Detectors
5816
Door/Window
Miniature
Transmitter
ECP Bus
Symphony
VGM (PTVGM)
Vista
Gateway
Module
5890
Wireless PIR
PassPoint
Vista-128FBP Vista-128FBP
Panel Linking
Module
Panel Linking
Module
Vue de la page 2
1 2 3 4 5

Commentaires sur ces manuels