POLLING LOOP CURRENT DRAW WORKSHEET
RPM DEVICE CURRENT
# UNITS
TOTAL
CURRENT
4194 Contact lmA
4192SD Photo Smoke
0.4 mA
4192SDT Smoke w/Heat
0.4 mA
4192CP Ion Smoke
0.4 MA
4275 Dual PIR
lMA
4278 Quad PIR lrnA
4190 2-Zone RPM 1 MA (LOW)
2 MA(HIGH)
4208 8-Zone RPM 16mA
428063 Zone RF 40 mA
4280-88 Zone RF 40 mA
TOTAL **
● * If the total current draw exceeds 64 MA, a 4197 Loop Extender module must be used.
● * If using two 4280s or 4280-8s, you can power one of them from auxitiary power instead of using a 4197 bop
extender module.
AUXILIARY DEVICE CURRENT DRAW WORKSHEET
ID EVICE
i CURRENT
I # UNITS
I TOTAL
I
CURRENT
4137AD Console
60mA
5137AD Console 90 mA
6139 Console
100mA
675 Ground Start Module 50 mA
4280 or 4280-8 Receiver 40 mA
Built-in Pollinq LooP
(totalp II1001)
worksht)
4281 RF Receiver
35mA
5881 RF Receiver 50mA
4197 Poll Loop Extender
80 mA
●
●
●
TOTAL (750mA max)
● If using hard-wire devices such as PIRs, refer to the specificationsfor that particular unit’s current draw.
Only applies if powered from Control’s auxiliary power.
—