ADEMCO GROUP TECHNICAL SUPPORT KNOWLEDGEBASE
STEP -BY-STEP PROCEDURE
Created: 3.27.2000
Modified: 10.31.2001
File: V10se_23.Doc
Pages: 4
Page 1 of 4
Product: Vista-10SE
Title: E2 Programming for Wireless zones.
1. Enter Programming, Installers Code (4111) + 8 + 0 or Power down then back up
& press the * + # keys simultaneously within 50 seconds.
2. Screen Displays, “INSTALLER CODE 20”
3. Press “*” + 22 & enter 2 for wireless or 4 for RF jam detection.
4. Press “*” + 56, screen displays “ENTER ZN NUM. (00 = QUIT) 01”, if using
the *58 expert mode skip to step 15.
NOTE: Wireless zones use zone numbers 10-25.
5. Screen displays, “SET TO CONFIRM? 0 = NO , 1 = YES 0” enter 1 to confirm
the serial number & loop number are correct, otherwise 0.
6. Press 10 “*”, screen displays “ZN ZT - RC IN : L”
10 00 10 RF : 1
NOTE: This is a summary screen that displays the current values for this zone. ZN
is the zone number, ZT is the zone response type, RC is the report code, IN
is the input type & L is the loop number.
6. Press “*”, screen displays “10 ZONE TYPE ZONE DISABLED” enter the
desired value for this zone.
00 = NOT USED 09 = FIRE
01 = ENTRY/EXIT #1 10 = INTERIOR W/DELAY
03 = PERIMETER 20 = ARM-STAY*
04 = INTERIOR FOLLOWER 21 = ARM-AWAY*
05 = TRBLE DAY/ALARM NIGHT 22 = DISARM *
06 = 24Hr. SILENT 23 = NO ALARM RESPONSE
07 = 24Hr. AUDIBLE
08 = 24Hr. AUX.
NOTE:
* These zone types can only be used
for wireless zones.
7. Press “*” to continue, screen displays “10 REPORT CODE 1
ST
01 2
ND
00
10” & enter the report code for this zone.
NOTE: Report code values are in hexadecimal form & range from 01-15. A = 10,
but sends a 0 to central, B = 11, C = 12, D = 13, E = 14, & F = 15.
8. Press “*” to continue, screen displays “01 INPUT TYPE RF TRANS. 3” enter
the input type for this zone.
RF = (3)Supervised RF Transmitter (ex. 5816, 5817, 5890, 5806, etc.)
UR = (4)Unsupervised RF Transmitter (ex. 5802MN, 5802MN2, etc.)
BR = (5)Button RF (ex. 5804, 5804BD, 5802)
9. Press “*” to continue, screen displays “10 INPUT S/N L”
AXXX-XXXX 1
You can type in the serial number of the device or fault it to enroll.
Vue de la page 0
1 2 3 4

Résumé du contenu

Page 1

ADEMCO GROUP TECHNICAL SUPPORT KNOWLEDGEBASE STEP -BY-STEP PROCEDURE Created: 3.27.2000 Modified: 10.31.2001 File: V10se_23.Doc Pages: 4 Page

Page 2 - Pages: 4

ADEMCO GROUP TECHNICAL SUPPORT KNOWLEDGEBASE STEP -BY-STEP PROCEDURE Created: 3.27.2000 Modified: 10.31.2001 File: V10se_23.Doc Pages: 4 Page

Page 3

ADEMCO GROUP TECHNICAL SUPPORT KNOWLEDGEBASE STEP -BY-STEP PROCEDURE Created: 3.27.2000 Modified: 10.31.2001 File: V10se_23.Doc Pages: 4 Page

Page 4

ADEMCO GROUP TECHNICAL SUPPORT KNOWLEDGEBASE STEP -BY-STEP PROCEDURE Created: 3.27.2000 Modified: 10.31.2001 File: V10se_23.Doc Pages: 4 Page

Commentaires sur ces manuels

Pas de commentaire