N5944-9PR 4/96 (See Instructions N5944-9)
4140XMPT2 PROGRAMMING FORM
Some fields are programmed for each partition (shown as shaded fields). See the PARTITION-SPECIFIC section for
programming these fields. Standard default (*97) values are shown in brackets [ ], otherwise default = 0.
Fields bordered by dotted line can be programmed using the #93 Menu mode.
*00 INSTALLER CODE | | |
Enter 4 digits, 0-9 [4140]
ASSIGN RESPONSE TYPE FOR ZONES
(Enter 00-10; see Response Types below) see fields 1*01-1*09 to program
response types for zones 28-87.
*02 *03 *04 *05
1 | 9 | 17 | 25 |
2 | 10 | 18 | 26 |
3 | 11 | 19 | 27 |
4 | 12 | 20 | 0|0
5 | 13 | 21 | 97 | polling loop short
6 | 14 | 22 | 95 | (1+✱ panic)
7 | 15 | 23 | 96 | (3+ # panic)
8 | 16 | 24 | 99 | (✱+ # panic)
RESPONSE TYPES: 00 = Disabled zone; 01 = Entry/Exit #1;
02 = Entry/Exit #2; 03 = Perimeter; 04 = Interior Follower;
05 = Day/Night; 06 = 24 hour Silent Alarm; 07 = 24 hour Audible Alarm;
08 = 24 hour Auxiliary; 09 = Fire; 10 = Interior, Delay; 20 = arm stay; 21
= arm away; 22 = disarm; 23= no alarm response
*09 ENTRY DELAY #1 |
*10 EXIT DELAY #1 |
*11 ENTRY DELAY #2 |
*12 EXIT DELAY #2 |
*13 ALARM SOUNDER DURATION |
*14 ZONE 9 FAST/SLOW RESPONSE
1=fast; [0= slow]; "0" for UL.
*15 KEYSWITCH ASSIGNMENT
Enter partition in which keyswitch used, 1-8; [0=disable]
*16 CONFIRMATION OF ARMING DING
*17 AC POWER LOSS SOUNDING
1=yes; [0=no]
*18 AC POWER LOSS ALARM
1=yes; [0=no]
*19 AC RANDOMIZE
1=randomize 10-40 min.; [0=no]
*20 PHONE MODULE ACCESS CODE | |
Enter 01-09 for 1st digit; 11 (for ✴) or 12 (for #) for [00] [11]
2nd digit. To disable phone module, enter 1st digit =00 & 2nd digit =
11
*21 DISABLE FIRE TIME-OUT
1=no timeout; [0=fire timeout]
*22 CONSOLE PANIC ENABLES 95 96 99
*23 MULTIPLE ALARMS
*24 EXPANSION ZONE (RF, RPM) TAMPER DISABLE
1=disable; [0=enable]
*25 BURG.TRIGGER FOR RESPONSE TYPE 8
[1=enable]; 0=disable
*26 INTELLIGENT TEST REPORTING
Set "0" for UL 1=yes, (no report sent if any other report was
recently sent); [0=no]
*27 TEST REPORT INTERVAL [024] | |
Enter interval in hours, 001-199; 000=no report ; Max. 024 for UL.
*28 POWER UP IN PREVIOUS STATE
[1=yes] 0=no; "1" for UL.
*29 QUICK ARM
*30 TOUCH-TONE OR ROTARY DIAL
1=TouchTone; [0=rotary]
*31 PABX ACCESS CODE | | | |
00-09; B-F (11-15)
*32 PRIM. SUBS. ACCT # | | | |
*33 PRIMARY PHONE NUMBER
Enter 0-9 for each digit
*34 SECONDARY PHONE NUMBER
Enter 0-9 for each digit
*35 DOWNLOAD PHONE No.
Enter 0-9 for each digit
*36 DOWNLOAD ID No.
|
| | | | | | |
Enter 00-09; A-F (10-15) [15 15 15 15 15 15 15 15]
*37 DOWNLOAD COMMAND ENABLES
0
Dialer System Not Remote Remote Remote Upload
Shutdwn Shutdwn Used Bypass Disarm Arm Program
See field 1*53 for Callback disable option; [1=enable]; 0=disable; For UL
installations, all options must be disabled.
*38 INHIBIT BYPASS OF A ZONE |
*39 OPEN/CLOSE REPORT FOR INSTALLER
*40 OPEN/CLOSE REPORTING FOR KEYSWITCH
1=enable; [0=disable]
*41 EOLR DISABLE (Zones 2-8)
[1=N.C.loops]; 0=EOLR supervision; Must be "0" for UL.
*42 DIAL TONE PAUSE
[0=5 seconds]; 1=11 seconds; 2=30 seconds; Must be "0" for UL.
*43 DIAL TONE DETECTION
[1=wait for true dial tone]; 0=pause, then dial
*44 RING DETECTION COUNT
|
01-14; 15=answering machine; [00=no detection]
*45 PRIMARY FORMAT
[0=Low Speed]; 1=Contact ID; 2=Ademco High Speed;
3=Ademco Express
*46 LOW SPEED FORMAT (Primary)
[0=Ademco Low Speed]; 1=Sescoa/Radionics
*47 SECONDARY FORMAT
[0=Low Speed]; 1=Contact ID; 2=Ademco High Speed;
3=Ademco Express
*48 LOW SPEED FORMAT (Sec.)
[0=Ademco Low Speed]; 1=Sescoa/Radionics
*49 CHECKSUM VERIFICATION
1=yes; [0=no] Prim Scndry
*50 SESCOA/RADIONICS SELECT
1=Sescoa; [0=Radionics]
*51 DUAL REPORTING
1=yes; [0=no] If used with Spilt Reporting "1" option (1*34), alarms
go to both primary & secondary numbers, while all other reports go
to secondary only. If used with Split Reporting "2" option,
open/close and test messages go to both lines, while all other
reports go to primary.